Technical specifications

Suitable for flush-mounted installationNo
Number of poles (total)4
Number of protected poles3
Rated voltage415V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated current25A
Rated fault current0.03A
Leakage current typeA
Power loss10.1W
Current limiting class3
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity according to IEC 60947-2-kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Disconnection characteristicUndelayed
Surge current capacity0.25kA
Voltage typeAC
Frequency50/60 Hz
Release characteristicC
Concurrently switching neutral conductorNo
With interlocking deviceYes
Over voltage category3
Pollution degree2
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings3
Flush-mounted installationNo
Built-in depth91mm
Anti-nuisance tripping versionNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL564111E0254 | FS403E-C25/0.03

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Number of poles (total)

4

Number of protected poles

3

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

25A

Rated fault current

0.03A

Leakage current type

A

Power loss

10.1W

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity according to IEC 60947-2

-kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

3

Flush-mounted installation

Built-in depth

91mm

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²