  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Built-in depth91mm
Release characteristicC
Pollution degree2
Over voltage category3
Leakage current typeF
Degree of protection (IP)IP20
Width in number of modular spacings4
Rated current10A
Rated short-circuit breaking capacity according to IEC 60947-225kA
Number of protected poles3
Frequency50/60 Hz
Current limiting class3
Surge current capacity3kA
Concurrently switching neutral conductorYes
Rated fault current0.03A
Rated voltage415V
Power loss4.9W
Rated insulation voltage Ui500V
Flush-mounted installationNo
Number of poles (total)4
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
With interlocking deviceYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core- - -mm²
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL564310E0104 | FS403MK-C10/0.03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

91mm

Release characteristic

C

Pollution degree

2

Over voltage category

3

Leakage current type

F

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Rated current

10A

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Number of protected poles

3

Frequency

50/60 Hz

Current limiting class

3

Surge current capacity

3kA

Concurrently switching neutral conductor

Rated fault current

0.03A

Rated voltage

415V

Power loss

4.9W

Rated insulation voltage Ui

500V

Flush-mounted installation

Number of poles (total)

4

Suitable for flush-mounted installation

Anti-nuisance tripping version

With interlocking device

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

- .. -mm²

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.