Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Rated current13A
Voltage typeAC
Rated insulation voltage Ui500V
Rated voltage415V
Built-in depth91mm
Frequency50/60 Hz
Surge current capacity3kA
Current limiting class3
Over voltage category3
Leakage current typeF
Pollution degree2
Rated fault current0.3A
Power loss5.4W
Rated short-circuit breaking capacity according to IEC 60947-225kA
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core- - -mm²
Degree of protection (IP)IP20
With interlocking deviceYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Number of protected poles3
Width in number of modular spacings4
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 6100910kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL564330E0134 | FS403MK-C13/0.3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Rated current

13A

Voltage type

AC

Rated insulation voltage Ui

500V

Rated voltage

415V

Built-in depth

91mm

Frequency

50/60 Hz

Surge current capacity

3kA

Current limiting class

3

Over voltage category

3

Leakage current type

F

Pollution degree

2

Rated fault current

0.3A

Power loss

5.4W

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

- .. -mm²

Degree of protection (IP)

IP20

With interlocking device

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

3

Width in number of modular spacings

4

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

10kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.