Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Power loss6W
Frequency0 - 0Hz
Rated current50A
Rated voltage-V
Number of poles (total)4
Rated insulation voltage Ui1500V
Number of protected poles4
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Current limiting class3
Release characteristicZ
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth82.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Width in number of modular spacings6
Pollution degree3
Over voltage category3
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS248362R0001 | S804U-UCZ50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Power loss

6W

Frequency

0 .. 0Hz

Rated current

50A

Rated voltage

-V

Number of poles (total)

4

Rated insulation voltage Ui

1500V

Number of protected poles

4

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Release characteristic

Z

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Flush-mounted installation

Concurrently switching neutral conductor

Width in number of modular spacings

6

Pollution degree

3

Over voltage category

3

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²

Degree of protection (IP)

IP20