Rated voltage-V
Built-in depth82.5mm
Number of poles (total)4
Release characteristicZ
Rated current60A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Frequency0 - 0Hz
Power loss6W
Voltage typeOther
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated insulation voltage Ui1500V
Rated impulse withstand voltage Uimp8kV
Number of protected poles4
Over voltage category3
Additional equipment possibleYes
Flush-mounted installationNo
Pollution degree3
Connectable conductor cross section solid-core0 - 70mm²
Width in number of modular spacings6
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 50mm²
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS248363R0001 | S804U-UCZ60

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

-V

Built-in depth

82.5mm

Number of poles (total)

4

Release characteristic

Z

Rated current

60A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

0 .. 0Hz

Power loss

6W

Voltage type

Other

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated insulation voltage Ui

1500V

Rated impulse withstand voltage Uimp

8kV

Number of protected poles

4

Over voltage category

3

Additional equipment possible

Flush-mounted installation

Pollution degree

3

Connectable conductor cross section solid-core

0 .. 70mm²

Width in number of modular spacings

6

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 50mm²

Explosion-proof

Ambient temperature during operating

-25 .. 60°C