Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current80A
Built-in depth82.5mm
Voltage typeOther
Rated voltage-V
Frequency0 - 0Hz
Pollution degree3
Current limiting class3
Release characteristicZ
Rated insulation voltage Ui1500V
Over voltage category3
Degree of protection (IP)IP20
Width in number of modular spacings6
Power loss6W
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired0 - 50mm²
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of poles (total)4
Additional equipment possibleYes
Flush-mounted installationNo
Explosion-proofNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section solid-core0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS248365R0001 | S804U-UCZ80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

80A

Built-in depth

82.5mm

Voltage type

Other

Rated voltage

-V

Frequency

0 .. 0Hz

Pollution degree

3

Current limiting class

3

Release characteristic

Z

Rated insulation voltage Ui

1500V

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

6

Power loss

6W

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

0 .. 50mm²

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of poles (total)

4

Additional equipment possible

Flush-mounted installation

Explosion-proof

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section solid-core

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA