Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current40A
Built-in depth36mm
Voltage typeOther
Rated voltage230V
Frequency50 - 60Hz
Release characteristicC
Over voltage category3
Rated insulation voltage Ui440V
Width in number of modular spacings1
Pollution degree4
Current limiting class3
Degree of protection (IP)IP20
Explosion-proofNo
Number of protected poles2
Power loss-W
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS551103R8404 | S401E-C40NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

40A

Built-in depth

36mm

Voltage type

Other

Rated voltage

230V

Frequency

50 .. 60Hz

Release characteristic

C

Over voltage category

3

Rated insulation voltage Ui

440V

Width in number of modular spacings

1

Pollution degree

4

Current limiting class

3

Degree of protection (IP)

IP20

Explosion-proof

Number of protected poles

2

Power loss

-W

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Suitable for flush-mounted installation

Additional equipment possible

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.