Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth36mm
Rated current63A
Over voltage category3
Rated voltage230V
Current limiting class3
Release characteristicC
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Explosion-proofNo
Pollution degree4
Width in number of modular spacings1
Number of protected poles2
Power loss-W
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Concurrently switching neutral conductorNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS551103R8634 | S401E-C63NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

36mm

Rated current

63A

Over voltage category

3

Rated voltage

230V

Current limiting class

3

Release characteristic

C

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Explosion-proof

Pollution degree

4

Width in number of modular spacings

1

Number of protected poles

2

Power loss

-W

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Concurrently switching neutral conductor

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.