Aleta.hr
Main Product Image

2CCS553103R8324 | S403E-C32NP

Code: 1999844

ManufacturerABB
Catalog number2CCS553103R8324
EAN code7612271442897

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installationNo
Built-in depth82mm
Release characteristicC
Number of poles (total)4
Number of protected poles4
Rated current32A
Rated voltage400V
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Frequency50 - 60Hz
Power loss-W
Flush-mounted installationNo
Current limiting class3
Concurrently switching neutral conductorYes
Over voltage category3
Pollution degree4
Additional equipment possibleYes
Width in number of modular spacings4
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS553103R8324 | S403E-C32NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Built-in depth

82mm

Release characteristic

C

Number of poles (total)

4

Number of protected poles

4

Rated current

32A

Rated voltage

400V

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Power loss

-W

Flush-mounted installation

Current limiting class

3

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

4

Additional equipment possible

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.