Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth82.5mm
Rated current32A
Current limiting class3
Explosion-proofNo
Concurrently switching neutral conductorNo
Release characteristicOther
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 50mm²
Degree of protection (IP)IP20
Rated insulation voltage Ui1500V
Frequency0 - 0Hz
Pollution degree2
Connectable conductor cross section solid-core0 - 70mm²
Number of protected poles1
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings1.5
Over voltage category3
Power loss3.2W
Flush-mounted installationNo
Rated voltage-V
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861002R1537 | S801S-UCK32-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

82.5mm

Rated current

32A

Current limiting class

3

Explosion-proof

Concurrently switching neutral conductor

Release characteristic

Other

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 50mm²

Degree of protection (IP)

IP20

Rated insulation voltage Ui

1500V

Frequency

0 .. 0Hz

Pollution degree

2

Connectable conductor cross section solid-core

0 .. 70mm²

Number of protected poles

1

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

1.5

Over voltage category

3

Power loss

3.2W

Flush-mounted installation

Rated voltage

-V

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.