Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth82.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Width in number of modular spacings3
Connectable conductor cross section solid-core0 - 70mm²
Frequency0 - 0Hz
Current limiting class3
Rated current13A
Over voltage category3
Release characteristicOther
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated voltage-V
Explosion-proofNo
Number of protected poles2
Power loss4W
Degree of protection (IP)IP20
Pollution degree2
Ambient temperature during operating-25 - 60°C
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Rated insulation voltage Ui1500V
Connectable conductor cross section multi-wired0 - 50mm²
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862002R1135 | S802S-UCB13-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Width in number of modular spacings

3

Connectable conductor cross section solid-core

0 .. 70mm²

Frequency

0 .. 0Hz

Current limiting class

3

Rated current

13A

Over voltage category

3

Release characteristic

Other

Flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated voltage

-V

Explosion-proof

Number of protected poles

2

Power loss

4W

Degree of protection (IP)

IP20

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Rated insulation voltage Ui

1500V

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.