Aleta.hr
Main Product Image

2CCS864017R0557 | S804U-K40

Code: 1999912

ManufacturerABB
Catalog number2CCS864017R0557
EAN code7612271214234

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles4
Voltage typeOther
Built-in depth82.5mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated current40A
Release characteristicK
Number of poles (total)4
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated voltage-V
Rated insulation voltage Ui690V
Current limiting class3
Power loss3.7W
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Additional equipment possibleYes
Width in number of modular spacings6
Connectable conductor cross section multi-wired0 - 50mm²
Over voltage category3
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Pollution degree2
Explosion-proofNo
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864017R0557 | S804U-K40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

4

Voltage type

Other

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated current

40A

Release characteristic

K

Number of poles (total)

4

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated voltage

-V

Rated insulation voltage Ui

690V

Current limiting class

3

Power loss

3.7W

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

6

Connectable conductor cross section multi-wired

0 .. 50mm²

Over voltage category

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Pollution degree

2

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²