Technical specifications

Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Frequency50 - 60Hz
Built-in depth82.5mm
Number of protected poles4
Number of poles (total)4
Power loss8.3W
Release characteristicK
Rated voltage-V
Rated insulation voltage Ui690V
Voltage typeOther
Rated current100A
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
Pollution degree2
Flush-mounted installationNo
Additional equipment possibleYes
Width in number of modular spacings6
Over voltage category3
Connectable conductor cross section multi-wired0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864017R0637 | S804U-K100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Number of protected poles

4

Number of poles (total)

4

Power loss

8.3W

Release characteristic

K

Rated voltage

-V

Rated insulation voltage Ui

690V

Voltage type

Other

Rated current

100A

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

Pollution degree

2

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

6

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 50mm²