Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Built-in depth82.5mm
Number of poles (total)1
Rated current10A
Rated insulation voltage Ui690V
Rated voltage-V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Frequency50 - 60Hz
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss1.5W
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Voltage typeOther
Over voltage category3
Flush-mounted installationNo
Pollution degree2
Concurrently switching neutral conductorNo
Explosion-proofNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 70mm²
Width in number of modular spacings1.5
Connectable conductor cross section multi-wired0 - 50mm²
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS881017R0427 | S801U-K10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

82.5mm

Number of poles (total)

1

Rated current

10A

Rated insulation voltage Ui

690V

Rated voltage

-V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

1.5W

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Voltage type

Other

Over voltage category

3

Flush-mounted installation

Pollution degree

2

Concurrently switching neutral conductor

Explosion-proof

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 70mm²

Width in number of modular spacings

1.5

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C