Aleta.hr
Main Product Image

2CCS881017R0427 | S801U-K10

Code: 1999917

ManufacturerRAZNO
Catalog number2CCS881017R0427
Type
EAN code7612271214005

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

82.5mm

Number of poles (total)

1

Rated current

10A

Rated insulation voltage Ui

690V

Rated voltage

-V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 - 60Hz

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

1.5W

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Voltage type

Other

Over voltage category

3

Flush-mounted installation

No

Pollution degree

2

Concurrently switching neutral conductor

No

Explosion-proof

No

Additional equipment possible

Yes

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 - 70mm²

Width in number of modular spacings

1.5

Connectable conductor cross section multi-wired

0 - 50mm²

Ambient temperature during operating

-25 - 60°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS881017R0427 | S801U-K10

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

82.5mm

Number of poles (total)

1

Rated current

10A

Rated insulation voltage Ui

690V

Rated voltage

-V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

1.5W

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Voltage type

Other

Over voltage category

3

Flush-mounted installation

Pollution degree

2

Concurrently switching neutral conductor

Explosion-proof

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 70mm²

Width in number of modular spacings

1.5

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.