  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)1
Rated insulation voltage Ui690V
Release characteristicK
Number of protected poles1
Rated impulse withstand voltage Uimp8kV
Built-in depth82.5mm
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss4.3W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Current limiting class3
Frequency50 - 60Hz
Rated voltage-V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated current50A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree2
Width in number of modular spacings1.5
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Ambient temperature during operating-25 - 60°C
Explosion-proofNo
Flush-mounted installationNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS881017R0577 | S801U-K50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

1

Rated insulation voltage Ui

690V

Release characteristic

K

Number of protected poles

1

Rated impulse withstand voltage Uimp

8kV

Built-in depth

82.5mm

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

4.3W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Current limiting class

3

Frequency

50 .. 60Hz

Rated voltage

-V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated current

50A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

2

Width in number of modular spacings

1.5

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Flush-mounted installation

Degree of protection (IP)

IP20