Aleta.hr

Details

  • Low-voltage industrial components
  • Contactor relay
  • 1 KOM
  • ABB

Technical specifications

Mounting methodDIN-rail/screw
Width45mm
Rated operation current Ie, 400 V3A
Depth110.5mm
InterfaceNo
Number of auxiliary contacts as change-over contact0
With LED indicationNo
Rated control supply voltage Us at AC 50HZ400 - 415V
Rated control supply voltage Us at AC 60HZ480 - 480V
Connection type auxiliary circuitScrew connection
Number of auxiliary contacts as normally closed contact1
Suitable for manual operationNo
Rated switch current-A
Number of auxiliary contacts as normally open contact7
Height86mm
Rated control supply voltage Us at DC- - -V
Voltage type for actuatingAC
Number of auxiliary contacts as normally closed contact, delayed switching0
Number of auxiliary contacts as normally open contact, leading0
Rated operation current3A
Operating voltage at AC 60 Hz690 - 690V
Operating voltage at DC6 - 6V
Operating voltage at AC 50 Hz690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SBH131001R5171 | NFC71E-51

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Contactor relay
  • 1 KOM
  • ABB

Technical specifications

Mounting method

DIN-rail/screw

Width

45mm

Rated operation current Ie, 400 V

3A

Depth

110.5mm

Interface

Number of auxiliary contacts as change-over contact

0

With LED indication

Rated control supply voltage Us at AC 50HZ

400 .. 415V

Rated control supply voltage Us at AC 60HZ

480 .. 480V

Connection type auxiliary circuit

Screw connection

Number of auxiliary contacts as normally closed contact

1

Suitable for manual operation

Rated switch current

-A

Number of auxiliary contacts as normally open contact

7

Height

86mm

Rated control supply voltage Us at DC

- .. -V

Voltage type for actuating

AC

Number of auxiliary contacts as normally closed contact, delayed switching

0

Number of auxiliary contacts as normally open contact, leading

0

Rated operation current

3A

Operating voltage at AC 60 Hz

690 .. 690V

Operating voltage at DC

6 .. 6V

Operating voltage at AC 50 Hz

690 .. 690V