Aleta.hr

Details

  • Low-voltage industrial components
  • Contactor relay
  • 1 KOM
  • ABB

Technical specifications

Height86mm
Mounting methodDIN-rail/screw
Depth110.5mm
Width45mm
InterfaceNo
Rated control supply voltage Us at AC 60HZ240 - 260V
Number of auxiliary contacts as change-over contact0
Suitable for manual operationNo
Rated control supply voltage Us at AC 50HZ230 - 240V
Connection type auxiliary circuitScrew connection
Rated operation current3A
With LED indicationNo
Number of auxiliary contacts as normally closed contact, delayed switching0
Rated switch current-A
Rated control supply voltage Us at DC- - -V
Number of auxiliary contacts as normally open contact, leading0
Operating voltage at AC 50 Hz690 - 690V
Operating voltage at DC6 - 6V
Operating voltage at AC 60 Hz690 - 690V
Number of auxiliary contacts as normally open contact4
Number of auxiliary contacts as normally closed contact4
Rated operation current Ie, 400 V3A
Voltage type for actuatingAC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SBH131001R8839 | NFC33/11-88

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Contactor relay
  • 1 KOM
  • ABB

Technical specifications

Height

86mm

Mounting method

DIN-rail/screw

Depth

110.5mm

Width

45mm

Interface

Rated control supply voltage Us at AC 60HZ

240 .. 260V

Number of auxiliary contacts as change-over contact

0

Suitable for manual operation

Rated control supply voltage Us at AC 50HZ

230 .. 240V

Connection type auxiliary circuit

Screw connection

Rated operation current

3A

With LED indication

Number of auxiliary contacts as normally closed contact, delayed switching

0

Rated switch current

-A

Rated control supply voltage Us at DC

- .. -V

Number of auxiliary contacts as normally open contact, leading

0

Operating voltage at AC 50 Hz

690 .. 690V

Operating voltage at DC

6 .. 6V

Operating voltage at AC 60 Hz

690 .. 690V

Number of auxiliary contacts as normally open contact

4

Number of auxiliary contacts as normally closed contact

4

Rated operation current Ie, 400 V

3A

Voltage type for actuating

AC

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.