  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated voltage400V
Number of protected poles2
Number of poles (total)2
Release characteristicD
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp8kV
Voltage typeOther
Rated insulation voltage Ui690V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V30kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated current1A
Power loss3.2W
Frequency50 - 60Hz
Current limiting class3
Concurrently switching neutral conductorYes
Flush-mounted installationYes
Pollution degree3
Width in number of modular spacings3
Ambient temperature during operating-25 - 60°C
Over voltage category4
Connectable conductor cross section multi-wired0 - 50mm²
Additional equipment possibleYes
Explosion-proofNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019882R0001 | S802S-D1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated voltage

400V

Number of protected poles

2

Number of poles (total)

2

Release characteristic

D

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Voltage type

Other

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated current

1A

Power loss

3.2W

Frequency

50 .. 60Hz

Current limiting class

3

Concurrently switching neutral conductor

Flush-mounted installation

Pollution degree

3

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 60°C

Over voltage category

4

Connectable conductor cross section multi-wired

0 .. 50mm²

Additional equipment possible

Explosion-proof

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.