Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui690V
Rated voltage230V
Release characteristicK
Current limiting class3
Built-in depth82.5mm
Over voltage category4
Rated current1.6A
Voltage typeOther
Frequency50 - 60Hz
Pollution degree3
Power loss2.9W
Degree of protection (IP)IP20
Explosion-proofNo
Width in number of modular spacings1.5
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Number of protected poles1
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Connectable conductor cross section solid-core0 - 70mm²
Flush-mounted installationYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019939R0001 | S801S-K1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

690V

Rated voltage

230V

Release characteristic

K

Current limiting class

3

Built-in depth

82.5mm

Over voltage category

4

Rated current

1.6A

Voltage type

Other

Frequency

50 .. 60Hz

Pollution degree

3

Power loss

2.9W

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

1.5

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Number of protected poles

1

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Connectable conductor cross section solid-core

0 .. 70mm²

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.