Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Frequency50 - 60Hz
Built-in depth82.5mm
Rated voltage230V
Voltage typeOther
Rated insulation voltage Ui690V
Width in number of modular spacings1.5
Pollution degree3
Over voltage category4
Number of protected poles1
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Flush-mounted installationYes
Power loss2.2W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Explosion-proofNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section solid-core0 - 70mm²
Ambient temperature during operating-25 - 60°C
Rated current2A
Release characteristicK
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019940R0001 | S801S-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Rated voltage

230V

Voltage type

Other

Rated insulation voltage Ui

690V

Width in number of modular spacings

1.5

Pollution degree

3

Over voltage category

4

Number of protected poles

1

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Flush-mounted installation

Power loss

2.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Explosion-proof

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Rated current

2A

Release characteristic

K

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.