Technical specifications

Rated current2A
Current limiting class3
Frequency50 - 60Hz
Built-in depth82.5mm
Rated voltage230V
Voltage typeOther
Release characteristicK
Rated insulation voltage Ui690V
Width in number of modular spacings1.5
Pollution degree3
Over voltage category4
Number of protected poles1
Number of poles (total)1
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Flush-mounted installationYes
Power loss2.2W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Explosion-proofNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section solid-core0 - 70mm²
Ambient temperature during operating-25 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019940R0001 | S801S-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

2A

Current limiting class

3

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Rated voltage

230V

Voltage type

Other

Release characteristic

K

Rated insulation voltage Ui

690V

Width in number of modular spacings

1.5

Pollution degree

3

Over voltage category

4

Number of protected poles

1

Number of poles (total)

1

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Flush-mounted installation

Power loss

2.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Explosion-proof

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.