Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeOther
Current limiting class3
Frequency50 - 60Hz
Concurrently switching neutral conductorYes
Rated voltage230V
Rated insulation voltage Ui690V
Width in number of modular spacings1.5
Number of protected poles1
Over voltage category4
Power loss2W
Explosion-proofNo
Degree of protection (IP)IP20
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section multi-wired0 - 50mm²
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp8kV
Connectable conductor cross section solid-core0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V6kA
Flush-mounted installationYes
Rated current4A
Release characteristicK
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019943R0001 | S801S-K4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

Other

Current limiting class

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated voltage

230V

Rated insulation voltage Ui

690V

Width in number of modular spacings

1.5

Number of protected poles

1

Over voltage category

4

Power loss

2W

Explosion-proof

Degree of protection (IP)

IP20

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

8kV

Connectable conductor cross section solid-core

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Flush-mounted installation

Rated current

4A

Release characteristic

K

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.