  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Built-in depth82.5mm
Frequency50 - 60Hz
Rated current0.5A
Voltage typeOther
Rated voltage400V
Current limiting class3
Rated insulation voltage Ui690V
Width in number of modular spacings4.5
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Over voltage category4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Pollution degree3
Flush-mounted installationYes
Number of poles (total)3
Number of protected poles3
Additional equipment possibleYes
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 50mm²
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Connectable conductor cross section solid-core0 - 70mm²
Concurrently switching neutral conductorYes
Power loss6W
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019953R0001 | S803S-K0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Rated current

0.5A

Voltage type

Other

Rated voltage

400V

Current limiting class

3

Rated insulation voltage Ui

690V

Width in number of modular spacings

4.5

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Over voltage category

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Pollution degree

3

Flush-mounted installation

Number of poles (total)

3

Number of protected poles

3

Additional equipment possible

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Connectable conductor cross section solid-core

0 .. 70mm²

Concurrently switching neutral conductor

Power loss

6W

Rated impulse withstand voltage Uimp

8kV