Aleta.hr
Main Product Image

2CCF020063R0001 | S802HV-K4

Code: 2001658

ManufacturerRAZNO
Catalog number2CCF020063R0001
Type
EAN code7612271501297

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

4W

Voltage type

Other

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 - 60Hz

Rated voltage

-V

Release characteristic

K

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

1000V

Rated current

4A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

82.5mm

Number of poles (total)

2

Pollution degree

2

Over voltage category

3

Flush-mounted installation

Yes

Concurrently switching neutral conductor

Yes

Additional equipment possible

Yes

Width in number of modular spacings

3

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section multi-wired

0 - 50mm²

Degree of protection (IP)

IP20

Explosion-proof

No

Connectable conductor cross section solid-core

0 - 70mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCF020063R0001 | S802HV-K4

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

4W

Voltage type

Other

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Rated voltage

-V

Release characteristic

K

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

1000V

Rated current

4A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

82.5mm

Number of poles (total)

2

Pollution degree

2

Over voltage category

3

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.