Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth82.5mm
Rated voltage-V
Explosion-proofNo
Current limiting class3
Frequency50 - 60Hz
Rated insulation voltage Ui1000V
Number of protected poles2
Degree of protection (IP)IP20
Power loss3W
Width in number of modular spacings3
Over voltage category3
Pollution degree2
Connectable conductor cross section multi-wired0 - 50mm²
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Flush-mounted installationYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated current5A
Release characteristicK
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF020064R0001 | S802HV-K5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

82.5mm

Rated voltage

-V

Explosion-proof

Current limiting class

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

1000V

Number of protected poles

2

Degree of protection (IP)

IP20

Power loss

3W

Width in number of modular spacings

3

Over voltage category

3

Pollution degree

2

Connectable conductor cross section multi-wired

0 .. 50mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated current

5A

Release characteristic

K

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA