Aleta.hr
Main Product Image

2CCF030024R0001 | S801HV-K4

Code: 2001671

ManufacturerRAZNO
Catalog number2CCF030024R0001
Type
EAN code7612271501211

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

-V

Release characteristic

K

Voltage type

Other

Built-in depth

82.5mm

Number of poles (total)

1

Frequency

50 - 60Hz

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Rated insulation voltage Ui

1000V

Rated impulse withstand voltage Uimp

8kV

Power loss

2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated current

4A

Flush-mounted installation

Yes

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Additional equipment possible

Yes

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section solid-core

0 - 70mm²

Concurrently switching neutral conductor

Yes

Explosion-proof

No

Connectable conductor cross section multi-wired

0 - 50mm²

Width in number of modular spacings

1.5


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCF030024R0001 | S801HV-K4

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

-V

Release characteristic

K

Voltage type

Other

Built-in depth

82.5mm

Number of poles (total)

1

Frequency

50 .. 60Hz

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

3

Rated insulation voltage Ui

1000V

Rated impulse withstand voltage Uimp

8kV

Power loss

2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated current

4A

Flush-mounted installation

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 70mm²

Concurrently switching neutral conductor

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Width in number of modular spacings

1.5

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.