Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Number of poles (total)2
Rated insulation voltage Ui1000V
Rated impulse withstand voltage Uimp8kV
Rated voltage-V
Rated current0.5A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Release characteristicK
Number of protected poles2
Frequency50 - 60Hz
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss4W
Current limiting class3
Flush-mounted installationYes
Over voltage category3
Additional equipment possibleYes
Concurrently switching neutral conductorYes
Pollution degree2
Width in number of modular spacings3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 50mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF030025R0001 | S802HV-K0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Number of poles (total)

2

Rated insulation voltage Ui

1000V

Rated impulse withstand voltage Uimp

8kV

Rated voltage

-V

Rated current

0.5A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Release characteristic

K

Number of protected poles

2

Frequency

50 .. 60Hz

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

4W

Current limiting class

3

Flush-mounted installation

Over voltage category

3

Additional equipment possible

Concurrently switching neutral conductor

Pollution degree

2

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.