Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Current limiting class3
Rated voltage-V
Voltage typeOther
Rated current2A
Built-in depth82.5mm
Over voltage category3
Rated insulation voltage Ui1000V
Pollution degree2
Frequency50 - 60Hz
Width in number of modular spacings3
Power loss4.4W
Explosion-proofNo
Number of protected poles2
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 70mm²
Flush-mounted installationYes
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 50mm²
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF030027R0001 | S802HV-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Current limiting class

3

Rated voltage

-V

Voltage type

Other

Rated current

2A

Built-in depth

82.5mm

Over voltage category

3

Rated insulation voltage Ui

1000V

Pollution degree

2

Frequency

50 .. 60Hz

Width in number of modular spacings

3

Power loss

4.4W

Explosion-proof

Number of protected poles

2

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 70mm²

Flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 50mm²

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.