Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage-V
Frequency50 - 60Hz
Pollution degree2
Explosion-proofNo
Width in number of modular spacings3
Release characteristicK
Rated current2.5A
Built-in depth82.5mm
Voltage typeOther
Current limiting class3
Over voltage category3
Rated insulation voltage Ui1000V
Degree of protection (IP)IP20
Power loss5W
Number of protected poles2
Concurrently switching neutral conductorYes
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 70mm²
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
Additional equipment possibleYes
Flush-mounted installationYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF030028R0001 | S802HV-K2.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

-V

Frequency

50 .. 60Hz

Pollution degree

2

Explosion-proof

Width in number of modular spacings

3

Release characteristic

K

Rated current

2.5A

Built-in depth

82.5mm

Voltage type

Other

Current limiting class

3

Over voltage category

3

Rated insulation voltage Ui

1000V

Degree of protection (IP)

IP20

Power loss

5W

Number of protected poles

2

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 70mm²

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.