Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Surge current capacity3kA
Rated current16A
Built-in depth91mm
Rated insulation voltage Ui500V
Frequency50/60 Hz
Voltage typeAC
Over voltage category3
Concurrently switching neutral conductorYes
Number of protected poles1
Rated voltage240V
Rated fault current0.03A
Pollution degree2
Power loss2.7W
Leakage current typeF
Release characteristicC
Width in number of modular spacings2
Degree of protection (IP)IP20
With interlocking deviceYes
Rated short-circuit breaking capacity according to IEC 60947-225kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Ambient temperature during operating-25 - 60°C
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Connectable conductor cross section solid-core- - -mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL562310E0164 | FS401KM-C16/0,03

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Surge current capacity

3kA

Rated current

16A

Built-in depth

91mm

Rated insulation voltage Ui

500V

Frequency

50/60 Hz

Voltage type

AC

Over voltage category

3

Concurrently switching neutral conductor

Number of protected poles

1

Rated voltage

240V

Rated fault current

0.03A

Pollution degree

2

Power loss

2.7W

Leakage current type

F

Release characteristic

C

Width in number of modular spacings

2

Degree of protection (IP)

IP20

With interlocking device

Rated short-circuit breaking capacity according to IEC 60947-2

25kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Connectable conductor cross section solid-core

- .. -mm²

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.