Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Leakage current typeA
Rated insulation voltage Ui500V
Voltage typeAC
Built-in depth91mm
Release characteristicC
Surge current capacity0.25kA
Rated voltage415V
Rated current20A
Rated fault current0.1A
Connectable conductor cross section solid-core- - -mm²
With interlocking deviceYes
Number of protected poles3
Flush-mounted installationNo
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-215kA
Pollution degree2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorYes
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Degree of protection (IP)IP20
Number of poles (total)4
Power loss7.5W
Width in number of modular spacings4
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
Current limiting class3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCL563120E0204 | FS403M-C20/0.1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Leakage current type

A

Rated insulation voltage Ui

500V

Voltage type

AC

Built-in depth

91mm

Release characteristic

C

Surge current capacity

0.25kA

Rated voltage

415V

Rated current

20A

Rated fault current

0.1A

Connectable conductor cross section solid-core

- .. -mm²

With interlocking device

Number of protected poles

3

Flush-mounted installation

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Degree of protection (IP)

IP20

Number of poles (total)

4

Power loss

7.5W

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

Current limiting class

3

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.