Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current6A
Voltage typeOther
Built-in depth94.5mm
Over voltage category3
Current limiting class3
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Rated voltage240V
Release characteristicC
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Power loss1.722W
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Explosion-proofNo
Ambient temperature during operating-25 - 60°C
Width in number of modular spacings1
Connectable conductor cross section solid-core0.75 - 35mm²
Pollution degree4
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS471001R0064 | S451M-C6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

6A

Voltage type

Other

Built-in depth

94.5mm

Over voltage category

3

Current limiting class

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Rated voltage

240V

Release characteristic

C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

1.722W

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Explosion-proof

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

1

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

4

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA