Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth94.5mm
Rated voltage415V
Voltage typeOther
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Ambient temperature during operating-25 - 60°C
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Current limiting class3
Power loss4.468W
Explosion-proofNo
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Pollution degree4
Width in number of modular spacings2
Over voltage category3
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Rated current25A
Release characteristicC
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS472001R0254 | S452M-C25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

94.5mm

Rated voltage

415V

Voltage type

Other

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Power loss

4.468W

Explosion-proof

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Pollution degree

4

Width in number of modular spacings

2

Over voltage category

3

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Rated current

25A

Release characteristic

C

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA