Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Rated insulation voltage Ui440V
Width in number of modular spacings3
Release characteristicC
Frequency50 - 60Hz
Voltage typeOther
Rated current40A
Rated voltage415V
Explosion-proofNo
Power loss9.426W
Pollution degree2
Over voltage category3
Number of protected poles3
Connectable conductor cross section solid-core0.75 - 35mm²
Number of poles (total)3
Degree of protection (IP)IP20
Additional equipment possibleYes
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Built-in depth75mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS473001R0404 | S453M-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Rated insulation voltage Ui

440V

Width in number of modular spacings

3

Release characteristic

C

Frequency

50 .. 60Hz

Voltage type

Other

Rated current

40A

Rated voltage

415V

Explosion-proof

Power loss

9.426W

Pollution degree

2

Over voltage category

3

Number of protected poles

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of poles (total)

3

Degree of protection (IP)

IP20

Additional equipment possible

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Built-in depth

75mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.