Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated voltage400V
Frequency50 - 60Hz
Built-in depth91mm
Rated current1A
Rated insulation voltage Ui440V
Width in number of modular spacings2
Current limiting class3
Explosion-proofNo
Over voltage category3
Power loss4.4W
Degree of protection (IP)IP20
Pollution degree2
Release characteristicOther
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of protected poles2
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS562001R1014 | S402M-UCC1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated voltage

400V

Frequency

50 .. 60Hz

Built-in depth

91mm

Rated current

1A

Rated insulation voltage Ui

440V

Width in number of modular spacings

2

Current limiting class

3

Explosion-proof

Over voltage category

3

Power loss

4.4W

Degree of protection (IP)

IP20

Pollution degree

2

Release characteristic

Other

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of protected poles

2

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA