Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated current0.5A
Width in number of modular spacings2
Rated voltage400V
Current limiting class3
Explosion-proofNo
Built-in depth91mm
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category3
Voltage typeOther
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Release characteristicOther
Rated insulation voltage Ui440V
Pollution degree2
Additional equipment possibleYes
Power loss4W
Number of protected poles2
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Frequency50 - 60Hz
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS562001R1988 | S402M-UCZ0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated current

0.5A

Width in number of modular spacings

2

Rated voltage

400V

Current limiting class

3

Explosion-proof

Built-in depth

91mm

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

3

Voltage type

Other

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Release characteristic

Other

Rated insulation voltage Ui

440V

Pollution degree

2

Additional equipment possible

Power loss

4W

Number of protected poles

2

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Frequency

50 .. 60Hz

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA