Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current10A
Built-in depth75mm
Flush-mounted installationNo
Release characteristicD
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings1
Current limiting class3
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Over voltage category3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Rated insulation voltage Ui440V
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of protected poles1
Power loss1.6W
Pollution degree3
Voltage typeOther
Explosion-proofNo
Rated voltage230V
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571001R0101 | S401M-D10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

10A

Built-in depth

75mm

Flush-mounted installation

Release characteristic

D

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

1

Current limiting class

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Over voltage category

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Rated insulation voltage Ui

440V

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of protected poles

1

Power loss

1.6W

Pollution degree

3

Voltage type

Other

Explosion-proof

Rated voltage

230V

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.