Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Rated current2A
Voltage typeOther
Rated voltage240V
Width in number of modular spacings1
Over voltage category3
Rated insulation voltage Ui440V
Release characteristicK
Frequency50 - 60Hz
Pollution degree3
Current limiting class3
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Power loss1.3W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Number of poles (total)1
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Number of protected poles1
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571001R0277 | S401M-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Rated current

2A

Voltage type

Other

Rated voltage

240V

Width in number of modular spacings

1

Over voltage category

3

Rated insulation voltage Ui

440V

Release characteristic

K

Frequency

50 .. 60Hz

Pollution degree

3

Current limiting class

3

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Power loss

1.3W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Number of poles (total)

1

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Number of protected poles

1

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.