Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Voltage typeOther
Rated current32A
Explosion-proofNo
Rated voltage230V
Frequency50 - 60Hz
Over voltage category3
Rated insulation voltage Ui440V
Pollution degree3
Number of protected poles1
Ambient temperature during operating-25 - 60°C
Power loss3.2W
Release characteristicB
Concurrently switching neutral conductorNo
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Current limiting class3
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings1
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571001R0325 | S401M-B32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Voltage type

Other

Rated current

32A

Explosion-proof

Rated voltage

230V

Frequency

50 .. 60Hz

Over voltage category

3

Rated insulation voltage Ui

440V

Pollution degree

3

Number of protected poles

1

Ambient temperature during operating

-25 .. 60°C

Power loss

3.2W

Release characteristic

B

Concurrently switching neutral conductor

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Current limiting class

3

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

1

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA