Technical specifications

Rated current50A
Rated voltage230V
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Current limiting class3
Voltage typeOther
Release characteristicB
Built-in depth75mm
Explosion-proofNo
Number of protected poles1
Power loss3.8W
Pollution degree3
Degree of protection (IP)IP20
Over voltage category3
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Width in number of modular spacings1
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of poles (total)1
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571001R0505 | S401M-B50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

50A

Rated voltage

230V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Current limiting class

3

Voltage type

Other

Release characteristic

B

Built-in depth

75mm

Explosion-proof

Number of protected poles

1

Power loss

3.8W

Pollution degree

3

Degree of protection (IP)

IP20

Over voltage category

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Width in number of modular spacings

1

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of poles (total)

1

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA