Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree2
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Built-in depth75mm
Over voltage category3
Width in number of modular spacings1
Current limiting class3
Rated current8A
Rated voltage230V
Voltage typeOther
Release characteristicOther
Number of protected poles1
Degree of protection (IP)IP20
Power loss1.8W
Explosion-proofNo
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 60°C
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Flush-mounted installationNo
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571001R1084 | S401M-UCC8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

2

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Built-in depth

75mm

Over voltage category

3

Width in number of modular spacings

1

Current limiting class

3

Rated current

8A

Rated voltage

230V

Voltage type

Other

Release characteristic

Other

Number of protected poles

1

Degree of protection (IP)

IP20

Power loss

1.8W

Explosion-proof

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Flush-mounted installation

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA