Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Voltage typeOther
Rated current10A
Rated voltage230V
Over voltage category3
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Pollution degree2
Release characteristicOther
Current limiting class3
Power loss2W
Explosion-proofNo
Width in number of modular spacings1
Number of protected poles1
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Number of poles (total)1
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571001R1108 | S401M-UCZ10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Voltage type

Other

Rated current

10A

Rated voltage

230V

Over voltage category

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Pollution degree

2

Release characteristic

Other

Current limiting class

3

Power loss

2W

Explosion-proof

Width in number of modular spacings

1

Number of protected poles

1

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Additional equipment possible

Number of poles (total)

1

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.