  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Rated current20A
Rated voltage230V
Voltage typeOther
Built-in depth75mm
Over voltage category3
Explosion-proofNo
Pollution degree2
Power loss2.2W
Width in number of modular spacings1
Degree of protection (IP)IP20
Current limiting class3
Release characteristicOther
Rated insulation voltage Ui440V
Number of protected poles1
Number of poles (total)1
Additional equipment possibleYes
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571001R1204 | S401M-UCC20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated current

20A

Rated voltage

230V

Voltage type

Other

Built-in depth

75mm

Over voltage category

3

Explosion-proof

Pollution degree

2

Power loss

2.2W

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Current limiting class

3

Release characteristic

Other

Rated insulation voltage Ui

440V

Number of protected poles

1

Number of poles (total)

1

Additional equipment possible

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA