Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82mm
Rated current6A
Explosion-proofNo
Voltage typeOther
Width in number of modular spacings2
Over voltage category3
Frequency50 - 60Hz
Rated voltage230V
Rated insulation voltage Ui440V
Pollution degree3
Power loss3.6W
Current limiting class3
Release characteristicB
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Degree of protection (IP)IP20
Number of protected poles2
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571103R8065 | S401M-B6NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82mm

Rated current

6A

Explosion-proof

Voltage type

Other

Width in number of modular spacings

2

Over voltage category

3

Frequency

50 .. 60Hz

Rated voltage

230V

Rated insulation voltage Ui

440V

Pollution degree

3

Power loss

3.6W

Current limiting class

3

Release characteristic

B

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Number of protected poles

2

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.