Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated voltage230V
Current limiting class3
Frequency50 - 60Hz
Rated current32A
Rated insulation voltage Ui440V
Built-in depth82mm
Release characteristicD
Over voltage category3
Explosion-proofNo
Pollution degree3
Width in number of modular spacings2
Degree of protection (IP)IP20
Number of protected poles2
Power loss6.2W
Concurrently switching neutral conductorYes
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)2
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571103R8321 | S401M-D32NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated voltage

230V

Current limiting class

3

Frequency

50 .. 60Hz

Rated current

32A

Rated insulation voltage Ui

440V

Built-in depth

82mm

Release characteristic

D

Over voltage category

3

Explosion-proof

Pollution degree

3

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Number of protected poles

2

Power loss

6.2W

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.