Voltage typeOther
Built-in depth82mm
Rated current4A
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Width in number of modular spacings2
Over voltage category3
Connectable conductor cross section solid-core0.75 - 35mm²
Frequency50 - 60Hz
Release characteristicK
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Power loss2.8W
Pollution degree3
Number of protected poles2
Current limiting class3
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Explosion-proofNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Rated voltage240V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571103R8337 | S401M-K4NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

82mm

Rated current

4A

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

2

Over voltage category

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Frequency

50 .. 60Hz

Release characteristic

K

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Power loss

2.8W

Pollution degree

3

Number of protected poles

2

Current limiting class

3

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Explosion-proof

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated voltage

240V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.