Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Built-in depth82mm
Release characteristicC
Frequency50 - 60Hz
Rated current40A
Rated voltage240V
Voltage typeOther
Power loss7.4W
Connectable conductor cross section multi-wired0.75 - 25mm²
Pollution degree3
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles2
Over voltage category3
Width in number of modular spacings2
Additional equipment possibleYes
Flush-mounted installationNo
Current limiting class3
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571103R8404 | S401M-C40NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Built-in depth

82mm

Release characteristic

C

Frequency

50 .. 60Hz

Rated current

40A

Rated voltage

240V

Voltage type

Other

Power loss

7.4W

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Pollution degree

3

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

2

Over voltage category

3

Width in number of modular spacings

2

Additional equipment possible

Flush-mounted installation

Current limiting class

3

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.