Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage230V
Built-in depth82mm
Frequency50 - 60Hz
Voltage typeOther
Concurrently switching neutral conductorYes
Explosion-proofNo
Number of protected poles2
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings2
Pollution degree3
Power loss11.2W
Current limiting class3
Over voltage category3
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated current63A
Release characteristicB
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS571103R8635 | S401M-B63NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Built-in depth

82mm

Frequency

50 .. 60Hz

Voltage type

Other

Concurrently switching neutral conductor

Explosion-proof

Number of protected poles

2

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

2

Pollution degree

3

Power loss

11.2W

Current limiting class

3

Over voltage category

3

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated current

63A

Release characteristic

B

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA