Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Frequency50 - 60Hz
Number of protected poles2
Over voltage category3
Current limiting class3
Degree of protection (IP)IP20
Rated voltage400V
Pollution degree3
Width in number of modular spacings2
Rated insulation voltage Ui440V
Voltage typeOther
Explosion-proofNo
Power loss3.4W
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Rated current10A
Release characteristicB
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS572001R0105 | S402M-B10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Frequency

50 .. 60Hz

Number of protected poles

2

Over voltage category

3

Current limiting class

3

Degree of protection (IP)

IP20

Rated voltage

400V

Pollution degree

3

Width in number of modular spacings

2

Rated insulation voltage Ui

440V

Voltage type

Other

Explosion-proof

Power loss

3.4W

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Rated current

10A

Release characteristic

B

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA