Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Voltage typeOther
Built-in depth75mm
Rated insulation voltage Ui440V
Power loss3.2W
Rated current1.6A
Width in number of modular spacings2
Pollution degree3
Degree of protection (IP)IP20
Explosion-proofNo
Frequency50 - 60Hz
Over voltage category3
Current limiting class3
Rated voltage240V
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles2
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS572001R0257 | S402M-K1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Voltage type

Other

Built-in depth

75mm

Rated insulation voltage Ui

440V

Power loss

3.2W

Rated current

1.6A

Width in number of modular spacings

2

Pollution degree

3

Degree of protection (IP)

IP20

Explosion-proof

Frequency

50 .. 60Hz

Over voltage category

3

Current limiting class

3

Rated voltage

240V

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

2

Concurrently switching neutral conductor

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.