Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Voltage typeOther
Rated current32A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Over voltage category3
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Explosion-proofNo
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Frequency50 - 60Hz
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Power loss6.2W
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Number of poles (total)2
Degree of protection (IP)IP20
Release characteristicD
Width in number of modular spacings2
Current limiting class3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS572001R0321 | S402M-D32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Voltage type

Other

Rated current

32A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Over voltage category

3

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Additional equipment possible

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Explosion-proof

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Frequency

50 .. 60Hz

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Power loss

6.2W

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Number of poles (total)

2

Degree of protection (IP)

IP20

Release characteristic

D

Width in number of modular spacings

2

Current limiting class

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.